Help and repairs

Starting your Apisolis, replacing a part, fixing a fault: every part of the device is sold separately and every step is explained here. An Apisolis is not replaced, it is repaired.

I have a problem with my Apisolis
The Apisolis Origin and an adjustable spanner: every part of the device can be replaced

Fix a fault

It no longer charges or switches on

Check the charger first

  1. Plug the Apisolis in with a different USB cable and a different USB mains charger.
  2. Do not use a power bank.

If the device charges again, the problem was the cable or the charger.

Then watch the LED while it charges

What you seePart at faultWhat to do
The LED stays off and the device gives a faint beepBatteryReplace the battery
The LED flashes red or orange, even after several hours of charging, sometimes irregularlyBatteryReplace the battery
The device charges but no longer holds its chargeBattery, then controller cardReplace the battery first; if the problem persists, the controller card
The LED stays off, with no beep at allController card or batteryDo the test below

Test: the LED stays off, with no beep at all

This test is done with the case open and requires a 24-hour wait.

  1. Undo the 4 screws and open the case.
  2. Disconnect the battery from the controller card and leave it disconnected for 24 hours. If a component on the card looks blackened or burnt, report it to after-sales.
  3. With the battery still disconnected, plug the USB cable into the device. Do you hear a faint beep?
  4. With the USB cable still plugged in, reconnect the battery.

To prevent this fault: recharge the device after every visit, and store it spout up, bellows open. Formula leaking into the case can damage the battery and the card.

It beeps red when switched on, even though it is charged

Check first

  1. The reservoir is pushed in all the way, and the coil is properly seated in the sealing part.
  2. Wipe the connection pins under the coil: liquid between the two can create a contact.

If the red beep continues, the most common cause is one of the two pins on the contactor card, which no longer springs back up and no longer touches the coil.

Check the pins

  1. Remove the reservoir.
  2. Look at the two gold pins at the bottom of the reservoir slot.
  3. They should be at the same height and spring back up when you press them.
The contactor card and its two pins

Temporary fix

  • Bend the coil contacts back so that they touch the pins;
  • or slip a small piece of aluminium foil into the hollow of the coil contact, facing the pin that no longer springs back up.

Permanent fix

Replace the contactor card.

The reservoir is cracked, or there is liquid
What you noticeWhat it isWhat to do
The reservoir is split or brokenThe reservoir needs replacingReplace the reservoir
Droplets on the case just after useCondensation, normal on any device that vaporises a liquidAfter each session, remove the reservoir and wipe the case with a dry cloth
Vapour escapes between the bellows and the caseNormal: vapour escapes through the rim of the bellows, which is not airtightNothing, unless the leak stops you using the device: in that case, report it to after-sales
The reservoir empties during storageA real leakFollow the checks below

If there is a real leak, check in this order

  1. Storage: the device is stored spout up, bellows open. Never put a clip on the bellows.
  2. The sealing part and the reservoir: a crack or a damaged sealing part lets the formula through. Replace the faulty part.
  3. The coil: a damaged wick lets too much liquid through. Replace the coil.

Has liquid reached the inside of the case? Report it to after-sales: a major leak can damage the battery and the card.

The current ULTEM reservoir is amber: this is the natural colour of the material, and it does not hide the liquid level.

It does not start (no 4 beeps)
  1. Check the action: device upright, spout down, open and close the bellows 3 times.
  2. No LED lights up? Follow “It no longer charges or switches on”.
  3. Have you just installed the upgrade pack? Follow “No beeps on start-up?”: the red spacer is there for exactly this case.
Another problem, or a part is broken
  1. A part is broken, damaged or lost: find it under “Replace a part”, with its procedure and the link to order it.
  2. Your problem does not match any section of this page: describe it to after-sales using the button below.

Start your Apisolis

The micro USB port under the device
1

Charge

Plug the supplied USB cable into the micro USB port under the device, then into a USB charger or a computer. The LED flashes while charging and turns solid green when the battery is full.

Soaking the coil in Native formula
2

Prepare the coil

Soak the coil in Native formula for at least 5 minutes, then place it in the sealing part. Heated dry, a coil burns out in a few seconds.

Filling the reservoir with Native formula
3

Fill and assemble

Pour the Native formula into the reservoir up to the top of the internal ribs. Insert the sealing part, with the coil, without letting it overflow. Push the reservoir into the device until it stops.

Starting up: 3 pumps of the bellows, spout down
4

Start

Device upright, spout down, open and close the bellows 3 times: 4 beeps confirm it has started. To switch it off: bellows closed, spout up, 3 seconds, 1 beep. When not in use, it switches itself off after 20 minutes.

The action that makes the vapour

Press the bellows all the way down, slowly, then release it fully. The magnet at the end of the bellows only triggers the heating at the end of its travel.

Short, partial squeezes, as on a traditional smoker, give weak vapour even though the device is working normally.

A full squeeze of the bellows produces the vapour

Good habits

  • After every visit, fully recharge the device: the battery does not cope well with deep discharges.
  • To store it, spout up and bellows open. Never put a clip on the bellows.
  • A quarter of an hour before use, lay it flat: the formula runs down and soaks the wick.
  • After every session, remove the reservoir and wipe the case and connectors, never with any liquid: the droplets are condensation.
  • Battery level, with the device switched off: bellows closed, spout up, 2 seconds. Red from 0 to 40%, orange from 40 to 80%, green from 80 to 100%.
  • Before winter, charge it to 100%, store it away from cold and damp, and check the level from time to time.

Leaks, weak vapour, coil life: everything is covered on the Apisolis care and use page.

Replace a part

Has a part failed on an Apisolis less than 2 years old? Do not order it: run the diagnosis and after-sales will send it to you under the warranty. The coil is a wear part and is not covered.

Open and close the case

The battery, the controller card, the contactor card and the magnetic detector sit inside the yellow case. Nothing is glued: everything slots together.

Opening

  1. Undo the 4 case screws.
  2. Open the case.
  3. Take a photo of the inside before touching anything: you will need it when you reassemble.

Closing

  1. Check that every part is in place, as in your photo.
  2. Close the case and screw the 4 screws back in.
  3. If the reservoir then feels stiff or gets stuck, loosen the screws slightly.

Part: Apisolis FHC Screw (Pack of 4)

Replace the coil

Before you start: soak the new coil in Native formula for at least 5 minutes. Heated dry, a coil burns out in a few seconds.

Remove the reservoir
1
Take the coil out of the sealing part
2
Take the sealing part out of the reservoir
3
Refit the coil and the sealing part
4 to 6
Refit the reservoir
7
  1. Remove the reservoir from the device.
  2. Take the used coil out of the sealing part.
  3. Take the sealing part out of the reservoir.
  4. Place the new, soaked coil in the sealing part.
  5. If needed, top up the Native formula to the top of the internal ribs of the reservoir.
  6. Put the sealing part back into the reservoir without letting the formula overflow.
  7. Push the reservoir back into the device until it stops.
  8. Check that there is no significant leak. Tiny leaks are normal.

We recommend replacing the coil 2 to 3 times a year to keep the vapour dense. Never scrape a coil: it damages the filament.

Part: Replacement coil

Replace the reservoir and the sealing part

The reservoir pack contains a new reservoir and a spare sealing part.

Remove the old reservoir
1
Coil into the sealing part, then into the reservoir
3 and 5
Fill the reservoir
4
Insert the reservoir
6
  1. Remove the old reservoir from the device. If it feels stiff, loosen the 4 case screws slightly.
  2. Take the coil and the sealing part out of the old reservoir.
  3. Place the coil in the new sealing part. A new coil must first be soaked in Native formula for at least 5 minutes.
  4. Fill the new reservoir with Native formula up to the top of the internal ribs.
  5. Insert the sealing part, with the coil, into the reservoir without letting the formula overflow.
  6. Push the reservoir into the device until it stops.
  7. Check that there is no significant leak. Tiny leaks are normal.

Parts: Pack Apisolis Native Tank + Sealing Part · Apisolis Sealing Part

Replace the battery
  1. Undo the 4 screws, open the case and take a photo of the inside.
  2. Disconnect the battery from the controller card.
  3. Remove the old battery and put the new one in the same place.
  4. Connect the new battery to the controller card.
  5. Close the case and screw the 4 screws back in.
  6. Put the device on charge: the LED flashes while charging and turns solid green once the battery is full.

To make the battery last: recharge the device after every apiary visit. Before winter, charge it to 100% and store it away from cold and damp.

Part: Apisolis Battery

Replace the contactor card
  1. Undo the 4 screws, open the case and take a photo of the inside.
  2. Remove the old contactor card and disconnect it.
  3. Connect the new card and put it in the same place as the old one.
  4. Close the case and screw the 4 screws back in. If the reservoir then feels stiff, loosen them slightly.
  5. Refit the reservoir and start the device: upright, spout down, open and close the bellows 3 times. You should hear 4 beeps.

Part: Apisolis Contactor Card

Replace the controller card
  1. Undo the 4 screws, open the case and take a photo of the inside.
  2. Disconnect the cables attached to the controller card.
  3. Remove the card: nothing is glued, everything slots together, so you may need to pull a little.
  4. Put the new card in the same place and reconnect each cable as in your photo.
  5. Close the case and screw the 4 screws back in.
  6. Put the device on charge: the LED should flash while charging.

Part: Apisolis Controller Card

Replace the magnetic detector

The magnetic detector is the small white tube inside the case.

  1. Undo the 4 screws, open the case and take a photo of the inside.
  2. Remove the old detector.
  3. Fit the new one in exactly the same place and the same way round: the orientation matters.
  4. Close the case, screw the 4 screws back in and start the device: upright, spout down, open and close the bellows 3 times. You should hear 4 beeps.

Part: Apisolis Magnetic Detector

Install the upgrade pack, the case or the bottom plate

The upgrade pack contains a new-generation case and bottom plate, which seal better, plus a red spacer. Keep the spacer to one side: you only need it if the device does not start once reassembled.

  1. Undo the 4 screws, open the case and take a photo of the inside.
  2. Remove the old bottom plate from the bellows. If it resists, lever it off gently with a small screwdriver.
  3. Fit the new bottom plate onto the bellows. It may be a little tight: this is normal.
  4. Move all the components from the old case into the new one, arranged as in your photo.
  5. Compare with the photo of the finished assembly below: the magnetic detector, the small white tube, must be properly seated and the right way round.
  6. Close the case, screw the 4 screws back in and start the device: upright, spout down, open and close the bellows 3 times. You should hear 4 beeps.
Case open after the upgrade: battery, card and magnetic detector in place
Finished assembly. The magnetic detector is the small white tube, bottom left.
Bottom plate on the bellows, showing where the red spacer goes
The red spacer goes into this hole in the bottom plate.

No beeps on start-up?

Place the red spacer in the magnetic detector slot in the bottom plate, as in the photo above. It moves the magnet slightly further away from the detector. The components inside the case stay where they are. Close the case, then repeat the start-up test. Still nothing? Report it to after-sales.

Received the case on its own? Skip steps 2 and 3. The bottom plate on its own? Skip step 4.

Parts: Upgrade Pack – Case and Bottom Plate · Apisolis Case · Apisolis Bottom Plate

Replace the bellows

The replacement bellows comes with its magnet but without a bottom plate: you reuse the one from your device.

  1. Undo the 4 screws, open the case and take a photo of the inside.
  2. Remove the bottom plate from the old bellows. If it resists, lever it off gently with a small screwdriver.
  3. Fit it onto the new bellows, the same way round as on the old one. It may be a little tight: this is normal.
  4. Check that the inside of the case is arranged as in your photo, then close it and screw the 4 screws back in.
  5. Start the device: upright, spout down, open and close the bellows 3 times. You should hear 4 beeps. No beeps? Report it to after-sales.

Part: Apisolis Bellows with Magnet

Fit the PETG tip

The PETG tip spreads the vapour and acts as a stand, so you can set the device down at the apiary.

  1. Slide the PETG tip onto the end of the original spout of your Apisolis.
  2. Check that it holds: once fitted, it should not move. If it moves, report it to after-sales.

Part: PETG tip for Apisolis

Warranty and after-sales

Register my warranty

The Apisolis comes with a 2-year warranty. Register your device online with the authentication number printed on the registration card supplied with the device.

Register my warranty

Contact after-sales

Choose your fault and follow the procedure. If your Apisolis still does not work, the after-sales form opens at the end. Reply by email within 3 days.

Start the diagnosis

The full manual

The Apisolis user manual, in French, English, Spanish, German and Italian.

Open the manual

A question that is not about a fault: buying, an order, distribution? Use the Contact page.

Patented formula.

Patented formulas

Our high quality formulas have been evaluated by Apilab®.
Award winning company.

Award Winning Company

Since its launch, Apisolis has won multiple innovation awards.
Responsive customer service.

Top Notch Service

Wherever you are, our team is here to help—Monday through Friday.
Fast growing company.

Fast Growing Company

Join us at our European HQ and help shape the future of beekeeping.